6. Parameter settings

The charging pile device parameter settings display the configurable items according to your device firmware version number. This list describes all possible results.

6.1. Maximum current

The device uses the maximum current by default, and you can adjust the working current within the range allowed by the device to adapt to the charging power in different situations.

Power

Range

3.5kW

6A~16A

7KW

6A~32A

9.6KW

6A~40A

11KW

6A~16A

22KW

6A~32A

6.2. Plug and Charge Mode

When the cable is plugged into the electric vehicle, the device will begin charging the electric vehicle.

6.3. Charging stops when the vehicle is disconnected

When the cable is disconnected from the electric vehicle, charging will stop.

6.4. LED brightness

The brightness of the device LED screen.

Type

Range

Brightness

1, 2, 3 (corresponding values: 20%, 50%, 100%)

6.5. Household current

Total current when connected to the device.

(This function is only relevant if you have connected CT Box to your device network. If you only have charging pile devices, you do not need to pay attention to this function.)

Type

Range

Household current

7-200A

6.6. -12V detection

When the -12V level detection is abnormal, the abnormal information will be displayed for you.

6.7. Random Delay

When charging is started via the app or by swiping the card, the charging pile device will randomly delay the current output based on the input value you provide for this setting. (For example, if the input is 10 minutes, after starting the charging, the charging pile device will randomly choose a time between 1-7 minutes, assuming it is 5 minutes, the device will output current 5 minutes later.)

Type

Range

Random Delay

0-60min

6.8. Sensor screen off

When the charging station device detects that there is no human activity around for more than a few minutes, the screen will be turned off to save energy.

6.9. Error information collection

The charging pile equipment will collect and report the logs generated during operation.

6.10. Offline IC card

When the charging pile device cannot connect to the network, if you need to use a card to start the charging pile device, you can use this function to manage the IC card. You can refer to this section.