6. Parameter settings
The charging pile device parameter settings display the configurable items according to your device firmware version number. This list describes all possible results.
6.1. Maximum current
The device uses the maximum current by default, and you can adjust the working current within the range allowed by the device to adapt to the charging power in different situations.
Power |
Range |
|---|---|
3.5kW |
6A~16A |
7KW |
6A~32A |
9.6KW |
6A~40A |
11KW |
6A~16A |
22KW |
6A~32A |
6.2. Plug and Charge Mode
When the cable is plugged into the electric vehicle, the device will begin charging the electric vehicle.
6.3. Charging stops when the vehicle is disconnected
When the cable is disconnected from the electric vehicle, charging will stop.
6.4. LED brightness
The brightness of the device LED screen.
Type |
Range |
|---|---|
Brightness |
1, 2, 3 (corresponding values: 20%, 50%, 100%) |
6.5. Household current
Total current when connected to the device.
(This function is only relevant if you have connected CT Box to your device network. If you only have charging pile devices, you do not need to pay attention to this function.)
Type |
Range |
|---|---|
Household current |
7-200A |
6.6. -12V detection
When the -12V level detection is abnormal, the abnormal information will be displayed for you.
6.7. Random Delay
When charging is started via the app or by swiping the card, the charging pile device will randomly delay the current output based on the input value you provide for this setting. (For example, if the input is 10 minutes, after starting the charging, the charging pile device will randomly choose a time between 1-7 minutes, assuming it is 5 minutes, the device will output current 5 minutes later.)
Type |
Range |
|---|---|
Random Delay |
0-60min |
6.8. Sensor screen off
When the charging station device detects that there is no human activity around for more than a few minutes, the screen will be turned off to save energy.
6.9. Error information collection
The charging pile equipment will collect and report the logs generated during operation.
6.10. Offline IC card
When the charging pile device cannot connect to the network, if you need to use a card to start the charging pile device, you can use this function to manage the IC card. You can refer to this section.